Building Codes, Listings and Project Requirements

Cookson understands that it’s difficult to stay up to date with ever evolving building codes, listings and project requirements. We created our Codes & Listings area to help provide you with what you need to know about how our products meet building codes and listings, or to help you find a product that meets the requirements for your particular project. Either way we’ve got you covered when it comes to Codes & Listings.

Listings by Category
  • UL Listings
  • UL Ratings Summary
  • Factory Mutual

    The following documents are excerpts from the FM Approval Guide that list Cookson product. A complete FM Approval Guide is available through the Factory Mutual Website.

  • Intertek Testing Services (Warnock Hersey) Test Report Numbers
  • ICC Evaluation Services, Inc.

    Per International Building Code® standards, the following Cookson fire products have been evaluated as compliant by ICC-ES for use in means of egress openings:

  • Specified Wind Load

    Cookson Coiling, Insulated Coiling and Fire doors can be configured to withstand the full range of specific wind load requirements including missile impact ratings. Specified wind load designs have been performance validated through third party testing to one or more of the following performance criteria:

    • ANSI/DASMA-108
    • ASTM E 330
    • Miami-Dade County test protocols TAS 201, TAS 202 and TAS 203
    • Florida Building Code (FBC)
    • Texas Department of Insurance (TDI)
    • Signed and Sealed Calculations

    Refer to the links below for specific wind load documentation on Cookson Doors:

  • Seismic Performance Calculations per ASCE 7-05

    Cookson can provide project specific seismic calculations for all Service, , Fire and doors that are mounted Face of Wall or Between Jambs to steel or masonry. Seismic performance validation is per ASCE 7-05.

  • Acoustical Testing Reports – Sound Transmission Class (STC) Rating
    • Temp-Pro Insulated Doors have an STC (Sound Transmission Class) rating up to 30 for the curtain and up to 22 for the entire assembly, as tested per ASTM E90, based on testing a complete, operable assembly.
    • Standard Insulated Doors tested at a 27 STC rating compared to a STC 19 for non-insulated doors. Test results based on testing a complete, operable door assembly.
    • Superimposed / double insulated curtain assemblies are also available with a minimum Sound Transmission Class STC 32 rating as tested per ASTM E90, based on testing a complete, operable door assembly.
    • Insulated Fire Door’s fire resistant mineral wool insulated curtains provide a sound transmission class STC 27 rating. Test results based on testing a complete, operable door assembly.
    • Kontrol Fire achieved an STC 41 when tested to today’s ASTM E90 standards by an independent laboratory.
    • Kontrol Sound achieved an STC 45 when tested to today’s ASTM E90 standards by an independent laboratory. Kontrol Space achieved STC 30.
For more information on Cookson and LEED, visit our LEED, Sustainability and Green Manufacturing page.